Neisseria meningitidis (Albrecht and Ghon) Murray
13113™
DOWNLOAD GENOME
LEARN ABOUT OUR ENHANCED AUTHENTICATION INITIATIVE
suggested reference strain for serogroup D.
Product category
Bacteria
Strain designation
M158 [37A]
Type strain
No
Genome sequenced strain
Yes
Isolation source
Spinal fluid
Product format
Freeze-dried
Storage conditions
2°C to 8°C
General
Preceptrol
No
Characteristics
Serotype
D
Comments
Suggested reference strain for serogroup D
Handling information
Medium
ATCC Medium 814: GC Agar/Broth Medium
Temperature
37°C
Atmosphere
95% Air, 5% CO2
Handling procedure
Open vial according to enclosed instructions.
Using a single tube of #814 broth (5 to 6 mL), withdraw approximately 0.5 to 1.0 mL with a Pasteur or 1.0 mL pipette. Rehydrate the entire pellet.
Aseptically transfer this aliquot back into the broth tube. Mix well.
Use several drops of the suspension to inoculate a #814 agar slant and/or plate.
Incubate the tubes and plate at 37°C for 24 to 48 hours in an atmosphere of 5% CO2. Loosen screw caps during incubation period.
Handling notes
Additional information on this culture is available on the ATCC® web site at www.atcc.org.
Quality control specifications
Verification method
Whole-genome Sequencing
History
Deposited as
Neisseria meningitidis (Albrecht and Ghon) Murray
Depositors
SE Branham
Chain of custody
ATCC <-- SE Branham <-- Chicago Dept. Hlth. 37A
Legal disclaimers
Intended use
This product is intended for laboratory research use only. It is not intended for any animal or human therapeutic use, any human or animal consumption, or any diagnostic use.
Warranty
The product is provided 'AS IS' and the viability of ATCC® products is warranted for 30 days from the date of shipment, provided that the customer has stored and handled the product according to the information included on the product information sheet, website, and Certificate of Analysis. For living cultures, ATCC lists the media formulation and reagents that have been found to be effective for the product. While other unspecified media and reagents may also produce satisfactory results, a change in the ATCC and/or depositor-recommended protocols may affect the recovery, growth, and/or function of the product. If an alternative medium formulation or reagent is used, the ATCC warranty for viability is no longer valid. Except as expressly set forth herein, no other warranties of any kind are provided, express or implied, including, but not limited to, any implied warranties of merchantability, fitness for a particular purpose, manufacture according to cGMP standards, typicality, safety, accuracy, and/or noninfringement.
Disclaimers
This product is intended for laboratory research use only. It is not intended for any animal or human therapeutic use, any human or animal consumption, or any diagnostic use. Any proposed commercial use is prohibited without a license from ATCC.
While ATCC uses reasonable efforts to include accurate and up-to-date information on this product sheet, ATCC makes no warranties or representations as to its accuracy. Citations from scientific literature and patents are provided for informational purposes only. ATCC does not warrant that such information has been confirmed to be accurate or complete and the customer bears the sole responsibility of confirming the accuracy and completeness of any such information.
This product is sent on the condition that the customer is responsible for and assumes all risk and responsibility in connection with the receipt, handling, storage, disposal, and use of the ATCC product including without limitation taking all appropriate safety and handling precautions to minimize health or environmental risk. As a condition of receiving the material, the customer agrees that any activity undertaken with the ATCC product and any progeny or modifications will be conducted in compliance with all applicable laws, regulations, and guidelines. This product is provided 'AS IS' with no representations or warranties whatsoever except as expressly set forth herein and in no event shall ATCC, its parents, subsidiaries, directors, officers, agents, employees, assigns, successors, and affiliates be liable for indirect, special, incidental, or consequential damages of any kind in connection with or arising out of the customer's use of the product. While reasonable effort is made to ensure authenticity and reliability of materials on deposit, ATCC is not liable for damages arising from the misidentification or misrepresentation of such materials.
固定電話:010-53515223
業(yè)務(wù)手機:18610886853,18610241664,18701099593,18971386853,18701098095
微信號碼:vrmte521(18610886853企業(yè)微信);18610241664;biobw0905(18701098095)
企業(yè)公眾號:800185668
官方郵箱:biobw11@sina.com(微生物菌種查詢網(wǎng))
投訴電話:biobw8888(18701099593)